- Tankless
- Gas – PROPANE
- Gas – NATURAL GAS
High Efficiency Condensing Tankless Water Heater
MODEL: NPE-180A2
High Efficiency Condensing Tankless Water Heater
NPE-180A2
Download
Overview
- 1/2″ gas pipe capable up to 24′
- Field convertible gas system
- Ultra condensing efficiency
- Dual stainless steel heat exchangers
- Low NOx emissions (20ppm)
- SCH 40, 2″ venting up to 75′
- Cascading capable
- EZNav multi-line control panel
- Built-in HotButton control panel
- Common vent up to 12 units
Dimensions
Width | 17.3″ (43.9 cm) |
Height | 27.4″ (69.6 cm) |
Depth | 13.2″ (33.5 cm) |
Connections Sizes
(A) Air Intake | 2″ |
(B) Exhaust Gas Vent | 2″ |
(C) Hot Water Outlet | 3/4″ |
(D) Gas Inlet | 3/4″ |
(E) Recirculation Inlet | 3/4″ |
(F) Consensate Outlet | 1/2″ |
(G) Cold Water Inlet | 3/4″ |
Certification Summary
All NPE-2 models are field convertible from NG to LP gas.
Product Approvals
CSA | Yes |
NSF (Standard 5) | Yes |
Low Lead (<0.25%) | Yes |
SCAQMD 1146.2 (NOx, <20ppm) | Yes |
AHRI Number | 206368357 |
Energy Star Certified | Yes |
Efficiency Ratings*
Uniform Energy Factor (UEF) | 0.95 |
MAX GPM (67ºF Rise) | 4.3 GPM (16.3 l/m) |
Annual Energy Consumption * (Residential)
Natural gas (Therms/Year) | 179.0 |
Propane (Gallons/Year) | 196 gal (741.9 L) |
Natural Gas Estimated Operating Cost** | $195 |
Propane Estimated Operating Cost** | $472 |
*Based on U.S. Department of Energy (DOE) test procedures.
** Based on a national avergae natural gas cost of $1.09/therm, propane cost of $2.41/gallon.
Certifications / Qualifications
Temperature Rise
Temp Rise | NPE-180A2 |
35 ºF (19.4 ºC) rate | 8.4 GPM (31.8 l/m) |
40 ºF (22.2 ºC) rate | 7.4 GPM (28 l/m) |
45 ºF (25 ºC) rate | 6.5 GPM (24.6 l/m) |
50 ºF (27.8 ºC) rate | 5.9 GPM (22.3 l/m) |
55 ºF (30.6 ºC) rate | 5.3 GPM (20.1 l/m) |
60 ºF (33.3 ºC) rate | 4.9 GPM (18.5 l/m) |
65 ºF (36.1 ºC) rate | 4.5 GPM (17 l/m) |
70 ºF (38.9 ºC) rate | 4.2 GPM (15.9 l/m) |
75 ºF (41.7 ºC) rate | 3.9 GPM (14.8 l/m) |
80 ºF (44.4 ºC) rate | 3.7 GPM (14 l/m) |
85 ºF (47.2 ºC) rate | 3.5 GPM (13.2 l/m) |
90 ºF (50 ºC) rate | 3.3 GPM (12.5 l/m) |
100 ºF (55.6 ºC) rate | 2.9 GPM (11 l/m) |
110 ºF (61.1 ºC) rate | 2.7 GPM (10.2 l/m) |
120 ºF (66.7 ºC) rate | 2.5 GPM (9.5 l/m) |
130 ºF (72.2 ºC) rate | 2.3 GPM (8.7 l/m) |
140 ºF (77.8 ºC) rate | 2.1 GPM (7.9 l/m) |
DHW Capacity
Model | NPE-180A2 |
Natural gas | 10,000 – 150,000 BTU/h (2.93 – 43.95 kWh) |
Propane | 10,000 – 150,000 BTU/h (2.93 – 43.95 kWh) |
Operating Cost
Navien Tankless | 179.0 therms | $195* |
Other Tankless | 228 therms | $249 |
50 Gallon Tank | 293 therms | $319 |
* Based on Energy Guide cost estimates using $1.09 per therm of natural gas. Cost is in US dollars.
Specifications
Heat capacity (input) | Natural gas | 10,000 – 150,000 BTU/h (2.93 – 43.95 kWh) |
Propane | 10,000 – 150,000 BTU/h (2.93 – 43.95 kWh) | |
Efficiency ratings | UEF (NG & LP) | 0.95 |
Flow rate (DHW) | 35 ºF temp rise | 8.4 GPM (31.8 l/m) |
45 ºF temp rise | 6.5 GPM (24.6 l/m) | |
67 ºF temp rise | 4.3 GPM (16.3 l/m) |
Dimensions | 17.3″ W x 27.4″ H x 13.2″ D (43.9 cm W x 69.6 cm H x 33.5 cm D) |
Boiler weight | 73 lbs (33.1 kg) |
Installation type | Indoor or outdoor wall-hung |
Ignition | Electronic ignition |
Water pressure | 15-150 PSI (1.055-10.545 kg/cm2) |
Natural gas supply pressure (from source) | 3.5″ WC to 10.5″ WC (0.87 Kpa to 2.61Kpa) |
Propane gas supply pressure (from source) | 8″ WC to 13″ WC (1.99 Kpa to 3.23 Kpa) |
Natural gas manifold pressure (min-max) | -0.03″ WC to -0.55″ WC (-0.0075 Kpa to -0.14 Kpa) |
Propane gas manifold pressure (min-max) | -0.2″ WC to -0.55″ WC (-0.005 Kpa to -0.14 Kpa) |
Minimum flow rate | 0.5 GPM (1.893 l/m), <0.01 GPM (0.04 l/m) option* |
Connection sizes | Cold water inlet | 3/4″ |
Hot water outlet size | 3/4″ | |
Gas inlet | 3/4″ | |
Power supply | Main supply | 120V AC, 60 Hz |
Maximum power consumption | 200 W (max 2 A), 350 W (max 4 A) with external pump connected | |
Materials | Casing | Cold rolled carbon steel |
Heat exchangers |
Primary heat exchanger: stainless steel Secondary heat exchanger: stainless steel |
|
Venting | Exhaust |
2″ or 3″ PVC, CPVC, approved polypropylene and stainless steel 2″ or 3″ special gas vent type BH (Class II, A/B/C) |
Intake |
2″ or 3″ PVC, CPVC, approved polypropylene and stainless steel 2″ or 3″ special gas vent type BH (Class II, A/B/C) |
|
Vent clearances |
0″ to combustibles |
High elevations | 10,100 feet for both NG or LP gas. Please refer to installation Manual for additional details and instructions. |
Safety Devices | Flame rod, APS, ingnition operation detector, water temperature high limit switch, exhaust temperature high limit sensor, power surge fuse, burner high limit fuse, vent installation detector (VID) |
*Available for NPE-A2 models configured in an optional ComfortFlow® recirculation mode. Energy consumption will increase when the system is configured for recirculation.
NPE-180A2 Features & Benefits
2" PVC venting up to 75 feet
Low exhaust gas temperatures allow use of PVC (including schedule 40 PVC), CPVC, popypropylene (rigid and flexible) and stainless steel venting, saving time and costs.
Vent Installation Detector (VID) for added safety.
Dual Venturi for field gas conversions
Dual Venturi system creates better combustion control and turndown ratio.
Dual stainless steel heat exchangers
for added durability
EZNav™ Multi-line control with built-in intuitive software
1/2" gas pipe capability up to 24'
(subject to local codes). Cuts installation time, no need to install new gas lines for retrofit applications.
Videos
Why switch to TANK
Why switch to TANKLESS
Why switch to HYBRID
Need Help?
We'll be more than happy to provide you with the proper expert advice tailored to your specific needs